The Standard of Accuracy
Laser-Based
LABMASTER® Model 1000A is designed to provide the ultimate in user-friendly operation while delivering calibration- quality accuracy and reproducibility. Our exclusive digital interferometer measures internal and external dimensions by comparing the measurement probe position to the wavelength of a laser light source, effectively coupling the wavelength of light to the part being measured.
Simple, Flexible and Fast
Our most automated ID/OD measuring system with a 40”(1016mm) direct reading range and an 80” (2032mm) capacity. Features include laser interferometer, computer control, air bearings, bi-directional probes, constant measuring force, and flexible fixturing. These features offer guaranteed repeatability and operator independent reproducibility with unmatched speed. Swivel, centering, tilt, and elevation adjustments are controlled with a press of a button or click of the mouse.
A Standard to Grow With
At Pratt & Whitney we’re committed to an ongoing development program that will produce a continuous stream of new or improved applications for the LABMASTER® product line. We're equally sensitive to the investment one makes in such an instrument. That's why we make all new developments reverse compatible to the very first LABMASTER we shipped
Guaranteed Service/A2LA Accredited
The LABMASTER® Model 1000A was designed with serviceability in mind. Our exclusive modular design facilitates problem isolation and field interchangeability. We offer a one-year warranty (longer available) and service personnel who receive factory training to provide you with experienced product supportand calibration services meeting ISO 17025 standards.
Specifications
Instrument Uncertainty:1,2
|
2 + 0.5LMicroinches (±2 std.dev.)
|
0.05 +0.5L/1000 Microns (±2 std. d
|
Repeatability: 1
|
1.6 Microinches (±2 std.dev.)
|
0.04 Microns (±2 std.dev.)
|
Resolution:
|
0.1Microinch
|
0.0025 Microns
|
Measurement Range: Internal: External:
|
0.02" to 81"
0 to 80"
|
0.5 to 2056mm 0 to 2032mm
|
DirectReading Range:
|
40"
|
1016mm
|
StandardContactForce:
|
0.5 ozf
|
0.14N
|
VariableForce:
|
2 to 40ozf
|
0.56 N to 11.12N
|
MeasuringProbe Geometry:
|
0.0625" radius
|
1.6mm radius
|
TableLiftRange:
|
1.5inches
|
38mm
|
ElectricalRequirements:
|
110-240V, 50-60Hz, 2 A, 240W
|
Pneumatic Requirements:
|
1.5SCFM at 50 psi
|
2.55m3/HRat 345kPa
|
Dimensions: 3 (Wx D x H)
|
70x 20 x 16inches
|
178x 51x 41cm
|
Weight:
|
300lbs.
|
137kgs.
|
Transducer:
|
Helium-Neon 632.8nm(red)
|
|
- Environmental conditions should be within 0.5°F (0.25°C), 0.05 in Hg (1.5mm Hg), and 25% relative humidity between mastering and measuring. Simply re-master if variation exceeds these conditions. Re-mastering takes less than 1-minute.
- Total measurement uncertainty will vary with grade of master and application.
- Instrument width is 81" (2058 mm) when 80" (2032 mm) probes are attached.
NIST Traceable
Labmaster’s exclusive Digital Interferometer-based sensor, accurately measures length by comparing the measurement probe position to the absolute wavelength of a laser light source.